Product Center

Flowmeter
Display Meter
Auto Control System
Pressure &Level
Velocity Meter

Location:Home - Products

Low Conductivity Electromagnetic Flowmeter

ABDT-LD series smart electromagnetic flowmeter is a relatively mature liquid measurement instrument suitable for measuring the volume flow of conductivity liquid (conductivity≥5µs/cm) and slurry in closed pipes.It is suitable for various acid,alkali and salt solutions,clear water,sea water,sewage, pulp, mud, mortar, pulp, coal water slurry, filling equipment (Baijiu, soy sauce, vinegar, fruit juice, mineral water, etc.) and low conductivity medium etc.It is widely used in industrial production process control,energy measurement, environmental protection,sewage treatment and other fields. 4~20mA current signal,pulse signal and it is combined with display, recording instrument, calculator or regulator for detection, calculation,adjustment and control of flow.

Telephone/whatsApp:+86 19953631088

Product Details

Overview

ABDT-LD series low conductivity electromagnetic flowmeter is a liquid measuring instrument specially used for measuring low conductivity media (conductivity ≥ 4.5μs/cm) , suitable for the flow measurement of various acid and alkali solutions, clear water, sea water and food grade liquid. It is widely used in industrial production process control, energy measurement, environmental protection and sewage treatment. It can output (4~20) mA current signal, pulse signal, etc.. It is coupled with the display, recording instrument, accumulation operator or regulator for flow detection, product calculation, adjustment and control.


Characteristics

ABDT-LD series low conductivity electromagnetic flowmeter has the following characteristics:

● It is not affected by changes in fluid density, viscosity, temperature, pressure and electrical conductivity. The linear measurement principles can achieve high precision measurements;

● No flow parts in measuring pipe, small pressure loss and low straight pipe section requirement;

● The nominal diameter DN15-DN600 covers a wide range,lining and electrodes that meet the requirements of measuring a variety of conductive fluids;

● The converter adopts programmable low frequency rectangular wave excitation, which improves the stability of flow measurement and small power loss;

● The converter adopts a 16-bit embedded microprocessor with full digital processing, fast operation speed, strong interference resistance, reliable measurement, high accuracy and flow measurement range up to 1500:1;

● High definition backlight LCD display, full Chinese character menu operation, easy to use, easy operation, easy to learn and easy to understand;

● RS485 digital communication signal output;

● It has the conductivity measurement function, which can determine whether the pipe of the sensor is fully filled, and has the self-inspection and self-diagnosis function;

● It uses SMD devices and surface mounting (SMT) technology with high circuit reliability;

● It can be used for the corresponding explosion-proof occasions.


Use environmental conditions

Ambient temperature: sensor (-25~+60) ℃; converter (-20~+ 60) ℃

Relative temperature: (5~85)%RH


Working conditions

Maximum fluid temperature: integrated type  ≤ 70℃

Separated type: PTFE lining   ≤ 80℃

Polyneoprene lining   ≤ 65℃   

High temperature rubber   ≤ 120℃

Polyurethane rubber lining   ≤ 60℃

PFA lining   ≤ 150℃

F46 lining   ≤ 110℃

Fluid conductivity   ≥ 5uS/cm


Product composition

The electromagnetic flowmeter consists of two parts: electromagnetic flow converter and electromagnetic flow sensor. 


Product type

When used to measure the low conductivity media, the ABDT-LD series electromagnetic flowmeter is only the integrated type. It can be used in the specified explosion-proof places.

The sensor is available with electrodes of seven different materials and a lining of six different materials.


Technical Performance Indicators of the Product

1. Execution standard: JB/T9248-2015

2. Maximum flow speed: 15m/s

3. Nominal general diameter: DN10,15, 20, 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600,700,800,1000,1200,1400,1600

4. Precision: 0.5%

5. Nominal pressure: (1.0, 1.6, 2.5, 4.0) MPa, Other specifications and standards may be subject to the user requirements.

6. Materials: electrode form and material

Electrode form can be divided into standard type, scraper type, removable type and the grounding electrode.

The electrode and grounding electrode materials are 7 kinds of 316L stainless steel, harden alloy B, harden alloy C, titanium, tantalum, platinum alloy, stainless steel coated with tungsten carbide.

Flange material: carbon steel, stainless steel (optional)

Grounding ring material: stainless steel

Door protection ring material: stainless steel, carbon steel.

7. Shell protection

IP65

8. Explosion-proof standards:

Explosion-proof grade: ExdmbIIC T6 Gb

9. Converter performance

Power supply: single-phase AC power (85-265) V, (45-63)Hz, power is less than 20W; DC power supply (11-40) VDC.

Converter display and programming operation: 4 film keys can set all parameters and can also program the converter by using foreign receiver or PC machine (RS485, RS232), high definition backlight LCD display, empty pipe detection and self-diagnosis function.

Digital communication: RS485, RS232, MODBUS and REMOTE, with lightning protection.

Output signal

Current output: two-way circuit, full isolation (0-10) mA/(4-20)mA; load resistance: (0-10) mA, (0-1.5) KΩ; (4-20)mA , (0-750) Ω.

Frequency output: forward and reverse flow output, the upper limit of output frequency can be set in the range of (1-5000) HZ. Transistor collector is with photoelectric isolation output in both directions. The external power supply is not more than 35V, and the maximum collector current is 250mA when it is turned on.

Pulse output: forward and reverse flow output, output pulse up to 5000cp/s. Pulse equivalents are 0.001L-1.0m3/cP. Pulse width is automatically set to 20ms or square wave. Open collector output of transistor with photoelectric isolation. The external power supply is not more than 35V, and the maximum collector current is 250mA when it is turned on.

Flow direction indication output: this flowmeter can measure fluid flow in positive and negative direction. The direction of the fluid flow can also be judged.High level of output + 10V for displaying forward flow, and low level of 0V for reverse fluid flow output.

Alarm output: two transistor collector open circuit alarm output with photoelectric isolation. The external power supply is not more than 35V, and the maximum collector current is 250mA when it is turned on. Alarm state: fluid air pipe, excitation line break, flow over limit.

Damping time: 0s-100s, optional


Electrode material selection

Electrode material

Features and use scope

316L

Applicable: 1. Domestic water, industrial water, raw water, well water and urban sewage.

2. Weak corrosive acid, alkali and salt solution.

Haynes metal B

Applicable: 1. The hydrochloric acid (concentration is less than 10%) and so on non-oxidized acids.

2. Sodium hydroxide(concentration is less than 50%), all concentrations of ammonium hydroxide alkali solution.

3. Phosphoric acid, organic acid.

Not applicable: Nitric acid.

Haynes metal C

Applicable: 1.Mixed acid, such as the mixed solution of chromic acid and sulfuric acid.

2. Oxidation salts such as Fe+++, Cu++, sea water.

Not applicable:the hydrochloric acid.

Ti

Applicable: 1. Salt, such as (1) chloride (chloride/magnesium and aluminum/calcium/ammonium/iron, etc.)

(2) Sodium salt,potassium salt, hypochlorite salt, sea water.

2.Potassium hydroxide, amine hydroxide and barium hydroxide alkali solution whose concentration are less than 50%;

Not applicable: hydrochloric acid, sulfuric acid, phospic acid, hydrofluoric acid and other reductive acid.

Ta

Applicable: 1. Hydrochloric acid (concentration is less than 40%), dilute sulfuric acid and concentrated sulfuric acid (excluding fuming sulfuric acid);

2. Chloride dioxide, iron chloride, hypochlorite,sodium cyanide, lead acetate, etc.;

3. Nitric acid (including fuming nitric acid) and other oxidizing acid, aqua regia whose temperature is less than 80 degrees;

4. Not applicable: alkali, hydrofluoric acid.

Platinum-iridium alloy

Applicable: Almost all acid, alkali and salt solutions (including fuming nitric acid, fuming sulfuric acid)

Not applicable: aqua regia, ammonium salt.

Tungsten carbide

Applicable: large worn medium,paper pulp,sewage,resistant to interference of solid particles;

Not applicable: inorganic acid, organic acid, chloride.


Lining material selection

Lining material

Main performance

Scope of application

PTFE

1. One of the most stable materials in plastic that can withstand boiling hydrochloric acid, sulfuric acid, nitric acid and aqua regia and it can resist strong acid and a variety of organic solvents.

2. Poor wear resistance and adhesion performance.

1. Temperature-resistant ≤ 80℃

2. Strong corrosive medium such as acid and alkali.

3. Sanitary medium.

Polyfluoroalkoxy (PFA)

1. Chemical stability, electrical insulation,  lubricity, non-viscosity and combustible properties are similar to F46, but the PFA material strength, aging resistance and temperature resistance are better than F46.

2. Good adhesion with metal and better wear resistance than PTFE, F46.

3. Low smoke, refractory, high temperature resistance and high temperature mechanical strength are higher than PTFE and F46.

1. Long-term use  temperature resistance ≤ 150℃.

2. It can be used to measure most strong corrosive mediums such as strong acid, strong alkali and strong oxidizer; but it is not for KOH, nitric acid, hydrofluoric acid, etc.

PDF-ethylene propylene F46

1. Chemical stability, electrical insulation, lubricity, non-viscosity and combustible properties are similar to PTFE, but the F46 material strength, aging resistance and temperature resistance are better than PTFE.

2. Good adhesion with metal and better wear resistance than PTFE.

3.Excellent anti-tear  performance.

1. Long-term use  temperature resistance ≤ 110℃

2. It can be used to measure most strong corrosive mediums such as strong acid, strong alkali and strong oxidizer, but it is not for KOH, nitric acid, hydrofluoric acid, etc.

Polyneoprene rubber

1. Excellent elasticity, good wear resistance.

2. It has resistance to corrosion of general low concentration acid, alkali and salt medium and it has no resistance to corrosion of oxidation medium.

1.Temperature resistance ≤ 65℃

2.Measure the general water, sewage, mud and mineral slurry.

Urethane rubber

1. Excellent wear resistance and good oil resistance.

2. High strength,good tear resistance, but the acid and alkaline resistance are poor.

1. Generally long-term temperature resistance≤ 60℃


Outline size

Outline and installation size of the electromagnetic flow sensor (in mm)



图片2.png

Nominal diameter

L

Flange dimensions (GB/T9119-2010)

D

K

d0

N

C

PN

10

200

90

60

14

4

14

4.0MP

15

200

95

65

14

4

14

20

200

105

75

14

4

16

25

200

115

85

14

4

16

32

200

140

100

18

4

18

40

200

150

110

18

4

18

50

200

165

125

18

4

20

65

200

185

145

18

8

20

1.6MP

80

200

200

160

18

8

20

100

250

220

180

18

8

22

125

250

250

210

18

8

22

150

300

285

240

22

8

24

200

350

340

295

22

12

26

250

450

405

355

26

12

29

300

500

445

400

22

12

26

1.0MP

350

500

505

460

22

16

30

400

600

565

515

26

16

32

450

600

615

656

26

20

36

500

600

670

620

26

20

38

600

600

780

725

30

20

42

700

700

910

840

36

24

38

800

800

1025

950

39

24

38

900

900

1125

1050

39

28

40

1000

1000

1255

1170

42

28

42

1200

1200

1455

1380

39

32

38

1400

1400

1675

1590

42

36

42

1600

1600

1915

1820

48

40

46


Installation precautions


Keep a long enough straight pipe section upstream and downstream of the electromagnetic flow sensor (D is the sensor diameter) as required in the figure below.


微信截图_20230605163243.png


Product Type Selection


电磁选型2023.11.jpg

 

Liquid Flow and Velocity Table






超声波流量计

LCT超声流量计采用时差法计算流量,利用先进的微处理数字技术,特别适用于区域供热,热源厂,换热站,暖通空调(空调制冷设备)、自来水等液体的流量测量。 LCT超声流量计包括流量传感器和流量转换器;流量传感器采用多声道超声波,分别测量管道内不同流体层的介质流速,由软件自动补偿计算管段内介质的截面流速。流量转换器采用高速混合信号处理CPU,配备高精度

View Products

涡街流量计

涡街流量计主要用于管道介质流体的流量测量,如气体、液体、蒸汽等多种介质,在测量工况体积流量时几乎不受流体密度、压力、温度、粘度等参数的影响。涡街流量计采用压电应力式传感器,可靠性高,使用寿命长,可在(-20-350)℃的工作温度范围内工作。有模拟标准信号,也有数字脉冲信号输出,容易与计算机等数字系统配套使用,是一种比较先进、理想的测量仪器。

View Products

FC6000智能流量积算仪

AOBO-FC6000智能流量积算仪是全新平台打造的智能型中英文菜单组态的通用型流量计算机,以更快的计算速度、更低的功耗、更可靠的工作性能来完成对蒸汽、气体、液体的流量计量演算功能,能实时在线对流体的温度、压力进行补偿,能同时接收流量、温度、压力等信号,信号可以是频率、电流、差压、电阻等类型,信号处理采用无开关触点、无电位器可调部件技术,使得计量

View Products

远程抄表系统

为了满足用户计量和节能的各种需求,我公司自主研发的适应各种不同用户需求的(能源管理)智能远程抄表系统,在软件和硬件方面采用标准化、可靠性设计、符合国家标准。广泛应用于热电、化工、天然气、造纸、制药、生物技术、城镇供暖等领域,经过几年来的实际运行,得到了客户的普遍认可。

View Products

Weifang AOBO

E-mail

Code