Location:Home - Products
Slurry type Electromagnetic Flowmeter
The ABDT-LD series slurry electromagnetic flow meter is a special electromagnetic flow meter designed for measuring high viscosity and uniform media such as sewage, pulp, slurry, cement slurry, mortar, and coal water slurry. The slurry type electromagnetic flowmeter adopts high and low frequency mixing excitation technology and unique slurry noise suppression and removal technology, effectively improving the ability to measure slurry, with good stability, and can accurately measure slurry flow with a concentration of up to 78% (solid content).
Product Details
Overview
The ABDT-LD series slurry type electromagnetic flowmeter is a special electromagnetic flowmeter dedicated for measuring slurry high-viscosity uniform medium such as sewage, pulp, slurry, mortar and coal slurry.The slurry type electromagnetic flow meter adopts high and low frequency mixed frequency excitation technology and unique slurry noise suppression and removal technology, which effectively improves the ability of measuring the slurry and has good stability and can accurately measure the slurry flow with a concentration of up to 78% (solid content).
Characteristic
ABDT-LD series slurry electromagnetic flowmeter is with the following characteristics:
●For bad working conditions, such as the fluid mixed with a high concentration of slurry, coal slurry, pulp and other slurry, a stable measurement can be achieved;
●Use high frequency excitation technology with strong interference resistance, reliable measurement and high precision.
●Regardless of the change of fluid density, viscosity, the linear measurement principle achieves high precision pressure;
●No resistance flow parts in the measuring pipe, small pressure loss and low straight pipe requirement;
●Sensor is with grounding electrode to achieve good grounding of the instrument;
●High-definition backlight LCD display, all-English menu operation, easy to use, easy operation, easy to learn and easy to understand;
●With the RS485 digital communication signal output;
●It has a two-way flow measurement function.
●It can be used for the corresponding explosion-proof occasions.
Use environmental conditions
Ambient temperature: sensor (-25~+60) ℃; converter (-20~+ 60) ℃
Relative temperature: (5~85)%RH
Working conditions
Maximum fluid temperature: integrated type ≤ 70℃;
Separated type: PTFE lining ≤ 80℃
Polyneoprene lining ≤ 65℃
High temperature rubber ≤ 120℃
Polyurethane rubber lining ≤ 60℃
PFA lining ≤ 150℃
F46 lining ≤ 110℃
Fluid conductivity ≥ 5uS/cm
Product composition
The electromagnetic flowmeter consists of two parts: electromagnetic flow converter and electromagnetic flow sensor. The separated type also requires a special two-layer shielded cable to connect the converter and sensor.
Product type
The ABDT-LD series electromagnetic flowmeter is divided into two structural forms: integrated type and separated type. It can be used in the specified explosion-proof places.
The sensor is available with electrodes of seven different materials and a lining of six different materials.
Technical Performance Indicators of the Product
1. Execution standard: JB/T9248-2015
2. Maximum flow speed: 15m/s
3. Nominal general diameter: DN10,15, 20, 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600,700,800,1000
4. Precision: 0.5%
5. Nominal pressure: (1.0, 1.6, 2.5, 4.0) MPa, Other specifications and standards may be subject to the user requirements.
6. Materials: electrode form and material
Electrode form can be divided into standard type, scraper type, removable type and the grounding electrode.
The electrode and grounding electrode materials are 7 kinds of 316L stainless steel, harden alloy B, harden alloy C, titanium, tantalum, platinum alloy, stainless steel coated with tungsten carbide.
Flange material: carbon steel, stainless steel (optional)
Grounding ring material: stainless steel
Door protection ring material: stainless steel, carbon steel.
7. Shell protection
IP65
IP68 is limited to the separated type sensors and excluding explosion proof structures.
8. Explosion-proof standards:
Explosion-proof grade: ExdmbIIC T6 Gb
9. Connection cable: Split type electromagnetic flowmeter, sensor and converter are connected by signal cable and the longest cable length should be less than 100m. The company provides free 10m cable with the meter.Insufficient parts shall be ordered.
10. Converter performance
Power supply: single-phase AC power (85-265) V, (45-63)Hz, power is less than 20W; DC power supply (11-40) VDC.
Converter display and programming operation: 4 film keys can set all parameters and can also program the converter by using foreign receiver or PC machine (RS485, RS232), high definition backlight LCD display, empty pipe detection and self-diagnosis function.
Digital communication: RS485, RS232, MODBUS and REMOTE, with lightning protection.
Output signal
Current output: two-way circuit, full isolation (0-10) mA/(4-20)mA; load resistance: (0-10) mA, (0-1.5) KΩ; (4-20)mA , (0-750) Ω.
Frequency output: forward and reverse flow output, the upper limit of output frequency can be set in the range of (1-5000) HZ. Transistor collector is with photoelectric isolation output in both directions. The external power supply is not more than 35V, and the maximum collector current is 250mA when it is turned on.
Pulse output: forward and reverse flow output, output pulse up to 5000cp/s. Pulse equivalents are 0.001L-1.0m3/cP. Pulse width is automatically set to 20ms or square wave. Open collector output of transistor with photoelectric isolation. The external power supply is not more than 35V, and the maximum collector current is 250mA when it is turned on.
Flow direction indication output: this flowmeter can measure fluid flow in positive and negative direction. The direction of the fluid flow can also be judged.High level of output + 10V for displaying forward flow, and low level of 0V for reverse fluid flow output.
Alarm output: two transistor collector open circuit alarm output with photoelectric isolation. The external power supply is not more than 35V, and the maximum collector current is 250mA when it is turned on. Alarm state: fluid air pipe, excitation line break, flow over limit.
Damping time: 0s-100s, optional
Converter menu structure and parameter settings
LCD display and keyboard definition
Keybutton function
The instrument has four keys, namely function key, down key, up key and exit key
Up key: Add 1 number at the cursor to select the screen upward display content.
Down key: subtract 1 at the cursor and select the screen downward display content.
Function key + down key: cursor moves left / lower LCD contrast (at the main interface).
Function key + up key: cursor moves right / increase LCD contrast (at the main interface).
Function key + exit key: enter the password input screen from the automatic measurement status; confirm the password input; enter the sub-menu; save parameters.
Exit key: return to the superior sub-menu; press for more than two seconds to release the automatic measurement state.
Electrode material selection
Electrode material | Features and use scope |
316L | Applicable: |
1. Domestic water, industrial water, raw water, well water and urban sewage. | |
2. Weak corrosive acid, alkali and salt solution. | |
Haynes metal B | Applicable: |
1. The hydrochloric acid (concentration is less than 10%) and so on non-oxidized acids. | |
2. Sodium hydroxide(concentration is less than 50%), all concentrations of ammonium hydroxide alkali solution. | |
3. Phosphoric acid, organic acid. | |
Not applicable: | |
Nitric acid. | |
Haynes metal C | Applicable: |
1.Mixed acid, such as the mixed solution of chromic acid and sulfuric acid. | |
2. Oxidation salts such as Fe+++, Cu++, sea water. | |
Not applicable: | |
the hydrochloric acid. | |
Ti | Applicable: |
1. Salt, such as (1) chloride (chloride/magnesium and aluminum/calcium/ammonium/iron, etc.);(2) Sodium salt,potassium salt, hypochlorite salt, sea water. | |
2.Potassium hydroxide, amine hydroxide and barium hydroxide alkali solution whose concentration are less than 50%; | |
Not applicable: | |
hydrochloric acid, sulfuric acid, phospic acid, hydrofluoric acid and other reductive acid. | |
Ta | Applicable: |
1. Hydrochloric acid (concentration is less than 40%), dilute sulfuric acid and concentrated sulfuric acid (excluding fuming sulfuric acid); | |
2. Chloride dioxide, iron chloride, hypochlorite,sodium cyanide, lead acetate, etc.; | |
3. Nitric acid (including fuming nitric acid) and other oxidizing acid, aqua regia whose temperature is less than 80 degrees; | |
Not applicable: | |
alkali, hydrofluoric acid. | |
Platinum-iridium alloy | Applicable: |
Almost all acid, alkali and salt solutions (including fuming nitric acid, fuming sulfuric acid) | |
Not applicable: | |
aqua regia, ammonium salt. | |
Tungsten carbide | Applicable: |
large worn medium,paper pulp,sewage,resistant to interference of solid particles; | |
Not applicable: | |
inorganic acid, organic acid, chloride. |
Lining material selection
Lining material | Main performance | Scope of application |
PTFE | 1. One of the most stable materials in plastic that can withstand boiling hydrochloric acid, sulfuric acid, nitric acid and aqua regia and it can resist strong acid and a variety of organic solvents. | 1. Temperature-resistant ≤ 80℃ |
2. Poor wear resistance and adhesion performance. | 2. Strong corrosive medium such as acid and alkali. | |
3. Sanitary medium. | ||
Polyfluoroalkoxy (PFA) | 1. Chemical stability, electrical insulation, lubricity, non-viscosity and combustible properties are similar to F46, but the PFA material strength, aging resistance and temperature resistance are better than F46. | 1. Long-term use temperature resistance ≤ 150℃. |
2. Good adhesion with metal and better wear resistance than PTFE, F46. | 2. It can be used to measure most strong corrosive mediums such as strong acid, strong alkali and strong oxidizer; but it is not for KOH, nitric acid, hydrofluoric acid, etc. | |
3. Low smoke, refractory, high temperature resistance and high temperature mechanical strength are higher than PTFE and F46. | ||
PDF-ethylene propylene F46 | 1. Chemical stability, electrical insulation, lubricity, non-viscosity and combustible properties are similar to PTFE, but the F46 material strength, aging resistance and temperature resistance are better than PTFE. | 1. Long-term use temperature resistance ≤ 110℃ |
2. Good adhesion with metal and better wear resistance than PTFE. | 2. It can be used to measure most strong corrosive mediums such as strong acid, strong alkali and strong oxidizer, but it is not for KOH, nitric acid, hydrofluoric acid, etc. | |
3.Excellent anti-tear performance. | ||
Polyneoprene rubber | 1. Excellent elasticity, good wear resistance. | 1.Temperature resistance ≤ 65℃ |
2. It has resistance to corrosion of general low concentration acid, alkali and salt medium and it has no resistance to corrosion of oxidation medium. | 2.Measure the general water, sewage, mud and mineral slurry. | |
Urethane rubber | 1. Excellent wear resistance and good oil resistance. | 1. Generally long-term temperature resistance≤ 60℃ |
2. High strength,good tear resistance, but the acid and alkaline resistance are poor. |
Outline size
Outline and installation size of the electromagnetic flow sensor (in mm)
Nominal diameter | L | Flange dimensions (GB/T9119-2010) | |||||
D | K | d0 | N | C | PN | ||
10 | 200 | 90 | 60 | 14 | 4 | 14 | 4.0MP |
15 | 200 | 95 | 65 | 14 | 4 | 14 | |
20 | 200 | 105 | 75 | 14 | 4 | 16 | |
25 | 200 | 115 | 85 | 14 | 4 | 16 | |
32 | 200 | 140 | 100 | 18 | 4 | 18 | |
40 | 200 | 150 | 110 | 18 | 4 | 18 | |
50 | 200 | 165 | 125 | 18 | 4 | 20 | |
65 | 200 | 185 | 145 | 18 | 8 | 20 | 1.6MP |
80 | 200 | 200 | 160 | 18 | 8 | 20 | |
100 | 250 | 220 | 180 | 18 | 8 | 22 | |
125 | 250 | 250 | 210 | 18 | 8 | 22 | |
150 | 300 | 285 | 240 | 22 | 8 | 24 | |
200 | 350 | 340 | 295 | 22 | 12 | 26 | |
250 | 450 | 405 | 355 | 26 | 12 | 29 | |
300 | 500 | 445 | 400 | 22 | 12 | 26 | 1.0MP |
350 | 500 | 505 | 460 | 22 | 16 | 30 | |
400 | 600 | 565 | 515 | 26 | 16 | 32 | |
450 | 600 | 615 | 656 | 26 | 20 | 36 | |
500 | 600 | 670 | 620 | 26 | 20 | 38 | |
600 | 600 | 780 | 725 | 30 | 20 | 42 | |
700 | 700 | 910 | 840 | 36 | 24 | 38 | |
800 | 800 | 1025 | 950 | 39 | 24 | 38 | |
900 | 900 | 1125 | 1050 | 39 | 28 | 40 | |
1000 | 1000 | 1255 | 1170 | 42 | 28 | 42 | |
1200 | 1200 | 1455 | 1380 | 39 | 32 | 38 | |
1400 | 1400 | 1675 | 1590 | 42 | 36 | 42 | |
1600 | 1600 | 1915 | 1820 | 48 | 40 | 46 |
Installation precautions
Keep a long enough straight pipe section upstream and downstream of the electromagnetic flow sensor (D is the sensor diameter) as required in the figure below.
Product Type Selection
Liquid Flow and Velocity Table
远程抄表系统
为了满足用户计量和节能的各种需求,我公司自主研发的适应各种不同用户需求的(能源管理)智能远程抄表系统,在软件和硬件方面采用标准化、可靠性设计、符合国家标准。广泛应用于热电、化工、天然气、造纸、制药、生物技术、城镇供暖等领域,经过几年来的实际运行,得到了客户的普遍认可。
View Products涡街流量计
涡街流量计主要用于管道介质流体的流量测量,如气体、液体、蒸汽等多种介质,在测量工况体积流量时几乎不受流体密度、压力、温度、粘度等参数的影响。涡街流量计采用压电应力式传感器,可靠性高,使用寿命长,可在(-20-350)℃的工作温度范围内工作。有模拟标准信号,也有数字脉冲信号输出,容易与计算机等数字系统配套使用,是一种比较先进、理想的测量仪器。
View Products超声波流量计
LCT超声流量计采用时差法计算流量,利用先进的微处理数字技术,特别适用于区域供热,热源厂,换热站,暖通空调(空调制冷设备)、自来水等液体的流量测量。 LCT超声流量计包括流量传感器和流量转换器;流量传感器采用多声道超声波,分别测量管道内不同流体层的介质流速,由软件自动补偿计算管段内介质的截面流速。流量转换器采用高速混合信号处理CPU,配备高精度
View Products