Location:Home - Products
Large Diameter Liquid Ultrasonic Flowmeter
The LCT Liquid ultrasonic flowmeter adopts the time difference method to calculate the flow and uses advanced micro-processing digital technology, which is especially suitable for the flow measurement of regional heating, heat source plant, heat exchange station, HVAC (air conditioning refrigeration equipment), tap water and other liquids. LCT Liquid ultrasonic flowmeter includes flow sensor and flow converter; Flow sensor adopts multi-channel ultrasonic wave to measure the medium flow speed of different fluid layers in the pipeline and automatically compensates the cross- section flow speed of the medium in the pipeline. Flow converter adopts a high speed mixed signal processing CPU and it is equipped with high precision time measurement system to achieve 1ps. It has fast dynamic response speed, making higher accuracy of flow speed measurement and repeatability and better stability.
Product Details
Overview
The LCT Liquid Ultrasonic flowmeter adopts the time difference method to calculate the flow and uses advanced micro-processing digital technology, which is especially suitable for the flow measurement of regional heating, heat source plant, heat exchange station, HVAC (air conditioning refrigeration equipment), tap water and other liquids.
Operational Principle
The LCT Liquid ultrasonic flowmeter adopts the measurement principle of time difference method. A sound wave travelling in the direction of flow of the product is propagated at a faster rate than one travelling against the flow, hence the acoustic signal transmission time has a difference (instant difference). The time difference method ultrasonic flowmeter is measured according to the specific principle of the specific relationship between the medium flow speed and the time difference. As long as the time upstream and downstream are accurately determined, the instantaneous flow speed can be found according to the flow speed and its specific relationship and then the instantaneous flow can be caculated.
Product Characteristics
(1) No cut-out online maintenance;
(2) Strong anti-bubble and anti-interference ability;
(3) The sensor resists high temperature and no water leakage;
(4) The dynamic response is up to 200 times per second;
(5) The turn-down rate is above 1:50;
(6) Measure the flow speed of different profiles for the best accuracy;
(7) Full-pass pipe section structure, with no pressure drop and stable flow speed;
(8) Integrated or remote type installation;
(9) 240*128 industrial large screen-LCD display;
(10) Measuring liquid is not affected by electrical conductivity;
(11) One-way up to 5000Hz high-speed pulse output;
(12) One-way standard (4-20) mA current output;
(13) M-BUS communication interface;
(14) RS232/485 interface, standard MODBUS protocol.
Technical Parameter(s)
Nominal general diameter: DN50-DN2000;
Measurement medium(s): clean single liquid;
Medium temperature: ≤130℃;
Accuracy: 1.0%;
Repeatability: 0.2%;
Turn-down rate: above 1:50
Case material: carbon steel; stainless steel;
Power supply: AC220V±10%, 50Hz or(10-36)VDC;
Signal output: pulse equivalent (0.01-9999) L/N (set), stability of 30ppm, standard current (4-20)mA output;
Communication output: M-BUS communication interface, RS232/485 interface, standard MODBUS protocol.
Flow Converter
The flow converter has a hardware temperature compensation circuit and software temperature compensation model, which is more suitable for heating high-temperature water metering compared to other flow meters to ensure the accuracy of flow measurement at different temperatures. Equipped with 6 multi-function buttons, industrial large screen LCD display, optional Chinese and English menu, humanized design and simple operation.
(1)Flow measurement
High-performance measurement chip, instrument instantaneous flow resolution 0.001m³/h, cumulative flow resolution 0.1L.
(2)Pulse output
The instrument can output 1-way of high-speed pulse, range (1-5000)Hz, pulse equivalent(0.01-9999.99)L/N can be set.
(3)Standard current signal output
The instrument can output a 1-way(4-20)mA signal.
(4)Standard current signal input
The instrument supports standard current signal input, measure range (4-20)mA, resolution 0.001mA.
Production Type Selection
FC6000 intelligent flow totalizer
AOBO-FC6000 intelligent flow totalizer is a universal flow computer with intelligent Chinese and English menu configuration built on a brand new platform. It completes the flow measurement and calculation functions for steam, gas, and liquid with faster calculation speed, lower power consumption, and more reliable working performance. It can compensate for the temperature and pressure of the fluid in real-time online, and can simultaneously receive signals such as flow, temperature, and pressure
View ProductsSteam/Hot Water IC Card Prepaid Intelligent Control System
In order to avoid billing disputes between energy supply and demand parties, reduce conflicts, and enable energy consuming units to consume clearly, Weifang Aobo Instrument independently developed and produced an IC card prepayment intelligent measurement and control system in 2008 that integrates early warning, anti-theft, and battery life functions, achieving a "payment before consumption" mode, completely solving the problems of difficult charging, meter reading, and management in thermal pow
View ProductsElectromagnetic Flowmeter
The ABDT-LD series intelligent electromagnetic flowmeter is a relatively mature liquid measurement instrument, suitable for measuring the volume flow rate of conductive liquids (conductivity ≥ 5 µ s/cm) and slurries in closed pipelines. It is suitable for various acid, alkali, salt solutions, clean water, seawater, sewage, mud, pulp, mineral pulp, low conductivity liquids, etc. Widely used in industrial production process control, energy metering, environmental protection, sewage treatment an
View ProductsVortex Flowmeter
Vortex flow meters are mainly used for measuring the flow rate of pipeline medium fluids, such as gases, liquids, steam, and other media. When measuring the volumetric flow rate under operating conditions, they are almost unaffected by parameters such as fluid density, pressure, temperature, and viscosity. The vortex flowmeter adopts a piezoelectric stress sensor with high reliability and long service life, and can operate within the operating temperature range of (-20-350) ℃. There are analog
View Products